Bop

Home>Topics>Bop
Refine Results
  1. All
  2. Online Articles
  3. Magazine Articles
  4. Videos
  1. DNV's findings on Deepwater Horizon BOP released

    Paula Dittrick Senior Staff Writer Federal officials have released a two-volume report from Det Norske Veritas (DNV) on the forensic examination of the Deepwater Horizon blowout preventer (BOP), and the report recommends additional study be done on the BOP's mobility to fully close and seal the Macondo well. On Apr. 20, 2010, a blowout of the Macondo well in about 5,000 ft of water off Louisiana resulted in explosions and fires killing 11 crew members on Transocean Ltd.'s Deepwater Horizon semisubmersible drilling rig. BP PLC operated the Macondo well. A massive oil spill resulted in the Gulf of Mexico. The Bureau of Ocean Energy Management, Regulation, and Enforcement/US Coast Guard Joint Investigation Team released DNV's report on the BOP, which concluded that off-centered drill pipe prevented the blind shear rams (BSR) from fully closing and sealing the wellbore. Transocean said, "The findings confirm that the BOP was in proper operating condition and functioned as designed. These results are consistent with the function and pressure tests conducted on the BOP in the days preceding the Macondo well blowout. High-pressure flow from the well created conditions that exceeded the scope of [the] BOP's design parameters." While releasing the report, BOEMRE announced a seventh session of public hearings starting Apr. 4 in New Orleans. The hearings will focus specifically on the BOP forensic examination. The forensic examination is one aspect of an investigation into the accident and subsequent oil spill. The full investigation report is not expected to be released until sometime this summer, BOEMRE said. Forensic testing The report said forces from the flow of the well induced the drill pipe to buckle between the upper annular and the upper variable bore rams (VBR). The drill pipe deflected until it contacted the wellbore just above the BSR. "This condition would have most likely occurred from the moment the well began flowing and would have remained until either the end conditions changed (change in upper annular or upper VBR state) or the deflected drill pipe was physically altered (sheared)," the report said. "The portion of the drill pipe located between the shearing blade surfaces of the BSRs was off center and held in this position by buckling forces." Drill pipe became trapped between the ram block faces, preventing the blocks from fully closing and sealing. "This position of the drill pipe between the upper annular and the upper VBRs led to buckling and bowing of the drill pipe within the wellbore," the report said. The BOP examination was completed after the BOP stack was raised from the sea floor on Sept. 4 and transferred to the NASA-Michoud complex in New Orleans. The blind shear, casing shear, and three sets of VBR were removed from the lower section of the BOP and examined both visually and using laser profilometry. DNV used high-definition video cameras and laser profilometry in its examination. Eight segments of drill pipe were recovered, examined, and tested. Two drill pipe segments were recovered from the BOP at Michoud. Three additional segments were recovered from the drilling riser at Michoud. Investigators also examined three other segments of drill pipe that had been previously recovered. Function testing of the AMF/Deadman autoshear indicated the voltage of the 27-v battery in the blue pod was insufficient to activate the higher-pressure BSR pilot solenoid mounted on the blue pod. Tests of the yellow pod BSR pilot solenoid circuits were inconsistent, the report said. Recommendations DNV recommends that industry examine and study potential conditions that could arise in the event of the loss of well control. It suggests numerous studies including: • Effects of the flow of the well fluids on BOP components and various tubulars that might be present. • Effects that could arise from the tubulars being fixed or constrained within the components of a BOP. • Ability of the BOP components to complete their intended design or function under these conditions. DNV also recommended industry study the ability of shear rams to completely cut tubulars and seal the well regardless of the tubulars position within the wellbore. "The findings of these studies should be considered and addressed in the design of future BOPs and the need for modifying current BOPs to address these findings," the report said. DNV also recommended industry examine and study the potential effects that closing of the annulars or closing of the VBRs could have on the BOP stack, including an evaluation of how elastic buckling of tubulars could adversely affect the ability to regain control of the well. More Oil & Gas Journal Current Issue Articles More Oil & Gas Journal Archives Issue Articles View Oil and Gas Articles on PennEnergy.com

    Magazine Articles

    Magazine Articles

    Mon, 28 Mar 2011

  2. BP to cut Macondo drill pipe; swap BOP

    Choppy seas delayed BP PLC's plans to retrieve the Transocean Ltd.'s Deepwater Horizon semisubmersible blowout preventer ( BOP ) with two pieces of pipe inside it and to install another BOP .

    Magazine Articles

    Magazine Articles

    Mon, 6 Sep 2010

  3. Government releases DNV's findings on Deepwater Horizon BOP

    Federal officials have released a two-volume report from Det Norske Veritas (DNV) on the forensic examination of the Deepwater Horizon blowout preventer ( BOP ), and the report recommends additional study be done on the BOP ’s failure to close and seal the Macondo well.

    Online Articles

    Online Articles

    Wed, 23 Mar 2011

  4. US House panel's hearing on gulf oil spill focused on BOP

    US House Energy and Commerce Committee members focused on possible blowout preventer ( BOP ) problems on May 12 in a second day of congressional hearings to examine the Apr. 20 semisubmersible rig accident and subsequent oil spill in the Gulf of Mexico.

    Online Articles

    Online Articles

    Thu, 13 May 2010

  1. BP retrieves Deepwater Horizon BOP from Macondo well in gulf

    Magazine Articles

    Magazine Articles

    Mon, 13 Sep 2010

  2. BP installs fully functioning BOP on Macondo

    BP PLC, operator of the deepwater Macondo well in the Gulf of Mexico, moved significantly closer to finishing a relief well when it lifted the Deepwater Horizon’s failed blowout preventer onto a vessel late Sept. 4 after having installed a different BOP on the well the previous day.

    Online Articles

    Online Articles

    Sun, 5 Sep 2010

  3. BP to cut Macondo drill pipe; swap BOP

    BP PLC was unable to remove three pieces of pipe from the blown-out Macondo well in the Gulf of Mexico, and it now plans to retrieve the Transocean Ltd.’s Deepwater Horizon semisubmersible blowout preventer ( BOP ) with two pieces of pipe inside it.

    Online Articles

    Online Articles

    Fri, 27 Aug 2010

  4. Macondo well BOP examination compromised, CSB chief tells Bromwich

    The US Chemical Safety and Hazard Investigation Board can’t meaningfully examine the Macondo well’s blowout preventer as long as the BOP ’s owner, Transocean Ltd., and manufacturer, Cameron International Inc., “have been granted unique access to the testing process,” CSB told the US Bureau of Ocean ...

    Online Articles

    Online Articles

    Mon, 27 Dec 2010

  5. TESTING IMPROVES SURFACE BOP EQUIPMENT RELIABILITY

    Michael E. Montgomery WEST Hou Inc. Houston Several fairly simple testing procedures can significantly improve the reliability and availability of surface blowout preventer ( BOP ) equipment. The reliability of surface BOP equipment has largely been assumed satisfactory, considering the relative ...

    Magazine Articles

    Magazine Articles

    Mon, 14 Jun 1993

  6. Multiplex BOP system utilizes updated technology, decreases riser disconnect time

    Transocean's Discoverer Seven Seas is poised to lower the multiplex BOP system on top of the stack. The BOP system is positioned beside the moon pool next to the derrick (Fig. 1). [28,499 bytes] The driller's panel mimics the BOP stack and other functions. Its location allows the toolpusher or ...

    Magazine Articles

    Magazine Articles

    Mon, 1 Dec 1997

  7. Weather delays Deepwater Horizon BOP swap

    Seas with 6-8 ft waves caused BP PLC and its contractors to wait for calmer weather before proceeding with plans to replace Transocean Ltd.’s Deepwater Horizon semisubmersible blowout preventer with another BOP , a federal spokesman said Aug. 30.

    Online Articles

    Online Articles

    Mon, 30 Aug 2010

  8. BIG BOP STACKS READY FOR SHELL'S AUGER PROJECT

    Custom designed subsea and surface blowout preventer ( BOP ) stacks are awaiting installation in Shell Offshore Inc.'s deepwater Auger oil and gas field development project in the Gulf of Mexico. Cooper Oil Tool and Shell engineers designed the BOPs specifically for Auger, a project scheduled to see ...

    Magazine Articles

    Magazine Articles

    Tue, 9 Feb 1993

Get More Results
Stay Connected